Following the usual instructions on the wiki, I took a broadband measurement followed by the simulines.
Start time:
PDT: 2023-08-31 12:35:20.025399 PDT
UTC: 2023-08-31 19:35:20.025399 UTC
GPS: 1377545738.025399
End time:
PDT: 2023-08-31 12:57:25.118313 PDT
UTC: 2023-08-31 19:57:25.118313 UTC
GPS: 1377547063.118313
2023-08-31 19:57:24,730 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOL
G_SS_20230831T193521Z.hdf5
2023-08-31 19:57:24,760 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCA
LY2DARM_SS_20230831T193521Z.hdf5
2023-08-31 19:57:24,771 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUS
ETMX_L1_SS_20230831T193521Z.hdf5
2023-08-31 19:57:24,782 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUS
ETMX_L2_SS_20230831T193521Z.hdf5
2023-08-31 19:57:24,793 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUS
ETMX_L3_SS_20230831T193521Z.hdf5
Note, this is the first measurement taken *after* the 2023-08-31 19:10 UTC calibration update (LHO:72594). Also, $ gpstime 1377545738 PDT: 2023-08-31 12:35:20.000000 PDT UTC: 2023-08-31 19:35:20.000000 UTC GPS: 1377545738