thomas.shaffer@LIGO.ORG - posted 14:00, Tuesday 05 September 2023 - last comment - 14:38, Tuesday 05 September 2023(72688)
Observing 2057 UTC
Back to observing at 2057UTC.
Maintenance recovery was slowed by ITMY CPS glitching (alog72683) that Jim fixed by replacing a CPS card. This was also the cause of some lock losses last night.
Comments related to this report
thomas.shaffer@LIGO.ORG - 14:24, Tuesday 05 September 2023 (72690)
We've had ITMY ST2 trip two more times since observing, but we haven't broken lock. Jim is preparing a new CPS card, but we'll have to break lock to do it if we choose to.
thomas.shaffer@LIGO.ORG - 14:38, Tuesday 05 September 2023 (72691)
We've had ITMY ST2 trip two more times since observing, but we haven't broken lock. Jim is preparing a new CPS card, but we'll have to break lock to do it if we choose to.
Intentionally broke to lock to fix allow for a fix of the CPS glitching. Relocking now.