Reports until 11:08, Wednesday 06 September 2023
H1 SEI
ryan.crouch@LIGO.ORG - posted 11:08, Wednesday 06 September 2023 (72708)
H1 ISI CPS Sensor Noise Spectra Check - Weekly

Closes FAMIS 25955

BSCs:

Script reports that the following are elevated.

ITMX_ST2_CPSINF_H1    
ITMX_ST2_CPSINF_H3

H1 doesn't look elevated but H3 does, V3 also looks elevated on ITMX ST2.

ITMY_ST2_CPSINF_V2 has reduced

HAMs:

HAM7_CPSINF_V3 looks a little elevated at higher frequencies

Everything else looks OK.

Non-image files attached to this report