Fixed Bug in CAL_CS_MASTER regarding KAPPA_UIM Gating Algorithm's Uncertainy Input
J. Kissel

After identifying a bug in the
    /opt/rtcds/userapps/release/cal/common/models/
        CAL_CS_MASTER.mdl
library that relates to the CAL-CS computation of KAPPA_UIM and its gating algorithm's uncertainy input (see LHO:72819), I've rectified the bug and committed the model change to the userapps repo as of rev 26218.

Attached is the "after" screenshot, which you can compare to LHO:72819's "before" screenshot.

Work permit to recompile the h1calcs model and install ASAP is forth-coming.