BBB channel dropped from Picket Fence

The BBB channel was continually going into the alarm range.  It's been removed from Picket Fence FOM and EPICS.

The steps for removal were:

1. Edited /opt/rtcds/userapps/release/isi/h1/scripts/Picket-Fence/LHO-picket-fence.py.  Commented out the block at line 39 that adds the "BBB" channel.

2. VNC to nuc5.  Close the Picket Fecne window.

3. ssh as controls to nuc5.  Run "start/launch.sh".  This restarts the Picket Fence FOM, which also sets the EPICS variables.

Comments related to this report
brian.lantz@LIGO.ORG - 09:55, Tuesday 19 September 2023 (72963)

Thanks Erik.

FYI - There are a bunch of stations around the Vancouver area, but BBB is the only one hosted by PNSN. We've reached out to see if we can get access to a similar low-latency server so that we can hopefully find a quieter station to use. These stations are useful for monitoring incoming motion from Alaska.