Displaying report 1-1 of 1.
Reports until 07:27, Tuesday 19 September 2023
H1 General (Lockloss)
ryan.crouch@LIGO.ORG - posted 07:27, Tuesday 19 September 2023 - last comment - 09:48, Tuesday 19 September 2023(72955)
Lockloss at 09:26TUC

The IFOs been struggling to relock following this LockLoss. It couldnt find DIFF IR a few times and I had to intervene (I only had to tap DIFF offset once or twice and it found it) and I ended up doing an initial alignment as it couldn't get  

past PRMI, we spent about 10 minutes in CARM_TO_TR before it said "NO IR IN arms" after the IA. It lost lock shortly after at 14:24UTC. 

Each relock seems to have the same trouble with DIFF IR, it being just 1 or 2 taps away but saying NO IR found

Comments related to this report
ryan.crouch@LIGO.ORG - 07:44, Tuesday 19 September 2023 (72957)

Lost lock at CARM_TO_TR again

ryan.crouch@LIGO.ORG - 09:48, Tuesday 19 September 2023 (72962)

The issue was it not actually finding IR and it rushing through CHECK_IR, so the solution would be to hold it CHECK_IR and let it fully find it and settle before moving on.

Images attached to this comment
Displaying report 1-1 of 1.