Reports until 11:58, Wednesday 31 July 2013
H1 SEI
sebastien.biscans@LIGO.ORG - posted 11:58, Wednesday 31 July 2013 (7299)
HEPI model needs an update - Switches buried in the model

Right now there is a mismatch between the MEDM HEPI screens and the model, more precisely in the BLND screen: three ON/OFF switches are still active but not displayed in the MEDM screen.

By default, the switches are OFF and the ouput of the BLND is 0 (see pictures attached).

This bug should disappeared in the last model version (we got rid of the switches). I'll try to put a WP and do the update this week.

 

For now, the quick solution is to use caput commands in the terminal. Example for HEPI-HAM3:

put the BLND L4C switche ON -> caput H1:HPI-HAM3_BLND_L4C_SWITCH 1

put the BLND IPS switche ON -> caput H1:HPI-HAM3_BLND_IPS_SWITCH 1

put the BLND BIAS switche ON -> caput H1:HPI-HAM3_BLND_BIAS_SWITCH 1

Images attached to this report