ryan.short@LIGO.ORG - posted 11:05, Thursday 21 September 2023 - last comment - 13:36, Thursday 21 September 2023(73033)
Lockloss @ 17:26 UTC

Lockloss @ 17:26 UTC - ISS secondloop looks to have saturated.

IMC_LOCK guardian noted at 17:26:05 "1st loop is saturated, and open" and moved to OPEN_ISS to open the secondloop. Upon entering the OPEN_ISS state, IMC_LOCK jumped to DOWN (I'm unsure exactly why) and after turning off the secondloop boosts, the lockloss occurred. I'll continue looking into this.

Images attached to this report
Comments related to this report
ryan.short@LIGO.ORG - 13:36, Thursday 21 September 2023 (73035)

The secondloop saturation may have been a red herring. Looking at the faster ASC-AS_A_DC channel, there's movement 290ms before the ISS turns off.

Images attached to this comment