Displaying report 1-1 of 1.
Reports until 13:52, Thursday 21 September 2023
H1 SQZ (ISC)
victoriaa.xu@LIGO.ORG - posted 13:52, Thursday 21 September 2023 - last comment - 14:58, Thursday 21 September 2023(73034)
Some recent hot/cold OM2 comparisons with sqz/no-sqz

To continue trying to understand how OM2 is improving range, I compared some recent sqz / no-sqz times with hot/cold OM2. So far, I still see the optical gain reduction with hot OM2 (i.e. cold OM2 is better >kHz), and the improvement in low-frequency noise with hot OM2 (~30-300 Hz?).

****Caveat regarding the calibration: I am simply plotting GDS-CALIB_STRAIN_NOLINES for these various times, but this is not the most accurate for the traces before September, as I did not use any corrections to GDS for those times.

I'm interested in this because OM2 was re-heated this week LHO:72967 after having been off for some time, possibly off since ~8/29. If we assume OM2 was cold on bad sqz night following 9/10, LHO:72796, and OM2 was hot & thermalized for today's 9/21 no-sqz time due to IO chassis power issues impacting HAM7 ISI LHO:73026 (reasonable to assume OM2 is hot; the remaining thermister 1 shows a plateau in temperature today) -- then we have some long quiet stretches to compare. For the sqz subtraction (ie, sqz dB as a function of frequency), last done with hot om2 on 8/2 for many sqz angles 72565, these long quiet sqz/no-sqz stretches are super useful. I'm still working on more IFO modelling to be more confident in quantum noise parameters as a function of OM2.

For reference, Camilla helped find the following sqz quiet times, building on the OM2 times used before in LHO:71533. A full dictionary of times used for plotting is attached.
'cold OM2 4':{  # bad sqz night @ https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=72796
                     'no sqz': {
                         'gps start': 1378445718, 
                         'gps stop' : 1378446918
                     },
                     'FDS': {
                         'gps start': 1378440000,
                         'gps stop' : 1378441800
                     }},
'hot OM2 4':{   # OM2 got cold sometime https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=72967
             # these hot sqz/no-sqz times are from 9/21 when ham7 isi tripped for several hours, https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=73020
                     'no sqz': {
                         'gps start': 1379340154,
                         'gps stop' : 1379345854
                     },
                     'FDS': {
                         'gps start': 1379324600,
                         'gps stop' : 1379328200
                     }},

Images attached to this report
Non-image files attached to this report
Comments related to this report
victoriaa.xu@LIGO.ORG - 14:58, Thursday 21 September 2023 (73036)

I think it's okay to assume OM2 was cold for the sqz data I pulled from 9/10-9/11. I checked trends of AS port alignments over the past 2 months which includes intentional OM2 cycling, and zoomed in from the past 1 month with an un-monitored temperature cycling. 

From the same times Daniel found in 72970, that is on Tuesday 8/29, we see about the same alignment shifts that Elenna saw in 70886 from changing OM2 temperature.

Looking at the trends, the alignment shifts with OM2 temps seem reasonably reproducible; I put a green box around trends which seemed the most correlated (i.e. OM1, 2, 3 and OMC SUS alignments). 

Images attached to this comment
Displaying report 1-1 of 1.