Displaying report 1-1 of 1.
Reports until 14:11, Monday 18 April 2011
X1 SUS
betsy.weaver@LIGO.ORG - posted 14:11, Monday 18 April 2011 - last comment - 14:15, Monday 18 April 2011(727)
Particulate Blow off
A MicroVac Portable ULPA Cleanroom Vacuum/Blower was purchased from Terra Universal.  After Class B'ing a TFE hose, we confirmed that particle counts coming out of the exhaust and through the TFE hose were near zero (after making sure that surrounding dust wasn't being picked up and slewing the counts).  Friday, we attempted to take some video/pictures of the blower hose blowing off particulate collected on a tabled QUAD UIM subassembly (see attached pictures). The field of view of the surface in the video is on the order of a few square inches.
Images attached to this report
Non-image files attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 14:13, Monday 18 April 2011 (731)
A different round of blowing in a different location of a UIM.
Images attached to this comment
betsy.weaver@LIGO.ORG - 14:15, Monday 18 April 2011 (732)
It's a bit difficult to quantify how much particulate is being removed, but it is clear from the photos/video that a significant portion of the macroscopic stuff is being removed.
Displaying report 1-1 of 1.