Observed noise lines in h(t) occurring intermittently, particularly at 15, 29, and 32 Hz, throughout the week
Lock-losses mostly caused by hardware/power issues, earthquakes, in some cases it looked like an earthquake caused a lock-loss but I could not find an obvious candidate in USGS
High microseism throughout the beginning of the week, range floated in the 140-145 Mpc range from Mon-Wed, began to improve once microseism had calmed down in the latter half of the week
Mon had both high microseism and high winds, however the detector managed to ride out most of it
Not much observing time on Tues due to maintenance
On Thurs the detector lost observing time due to a hardware problem + alignment difficulties when attempting re-lock
On Fri we noticed a regurly occurring ground motion in the corner station, which was picked up by multiple sensors and was weakly coupling to strain, as reported in this alog
Feature had appeared before, but not with the same frequency/regularity
Persisted throughout Fri/Sat, on Sun it changed and is now occurring less often, and more sporadically
Similar feature sometimes seen at LLO
DetChar suggested to follow-up by upconverting microphone data to audible range to help identify a cause
Better duty cycle and range during the weekend, Sun in particular was very quiet (almost to 160 Mpc on Sun)
Re-appearance of comb associated with OM2 heater (alog), later seemed to change frequency spacing
Few PyCBC triggers with chi2-weighted SNR above 10
H1:SUS-ETMX_L3_OPLEV_PIT_OUT_DQ and H1:ASC-DHARD_Y_OUT_DQ were frequently in the top two Hveto round winners for the week