H1 ISC
jeffrey.kissel@LIGO.ORG - posted 18:35, Wednesday 31 July 2013 (7316)
IMC In Limbo
[K. Izumi, J. Kissel, J. Rollins, S. Biscans, A. Pele]

We are in the middle transporting over LLO IMC stuff, but are calling it a night. 
We have installed new SUS-MC2 filters (but not committed to the repo yet) and changed the LOCK gains, but no other filter banks have changed.
We're in the process of updating the up and down scripts.

Thus the mode cleaner remains unlocked. 

State of the IFO this evening:

All suspensions that are on are damped at the same level they've been for the past two weeks.
HPI BS -- OFF, floating
ISI BS -- OFF, floating

HPI ITMY -- LOCKED
ISI ITMY -- Isolated Level 2

HPI HAM2 -- OFF, floating
ISI HAM2 -- Isolated Level 3

HPI HAM3 -- OFF, floating
Sebastian is running measurements on HAM3 ISI