(Cheryl, Corey, Keita)
The TMS Telescope & TMS In-Vacuum ISC Table were connected to each other today. It's a tight fit, but we were able to make the connection no worse for wear. After these were mated, we installed Tooling to suspend the system. While trying to install bars which mimic the suspension wires, we noticed that the threaded holes for a part (D1200310, Spreader Bar) of the ISC Table were bad (looks like the machinist didn't completely tap the hole and so the threads on one end of the hole were too tight for a bolt). We were able to remove the part, and will repair or fix the part, and then re-install it.
Started to set up for alignment with the green laser .