rahul.kumar@LIGO.ORG - posted 17:06, Sunday 01 October 2023 - last comment - 08:49, Monday 02 October 2023(73204)
New settings for ITMY mode 05/06

Since yesterday we have been struggling to damp ITMY mode 05/06. The nominal settings (with reduced gains) works for some time (as it worked yesterday) and then it turns around and starts getting worse. Hence, I tweaked the settings and found a new one which seems to be working for now (the drive and both the modes have been decreasing for the last few hours),

New settings: FM6+FM8+FM10 Gain -0.02 (phase +30)

I unsuccessfully tried the following two settings which made IY05 worse (while it was working fine for IY06),

FM6+FM10 Gain -0.02 - did not work for IY05, works for IY06 (no phase)
FM6+FM7+FM10 Gain -0.02 - did not work for IY05, works for IY06 (phase -30)

For now I have set the gains to zero on lscparams and would like to test the new settings manually for few locks before committing it in guardian.

I will keep watching the progress for the next few hours.

Images attached to this report
Comments related to this report
rahul.kumar@LIGO.ORG - 17:08, Sunday 01 October 2023 (73205)

We were kicked out of Observing for few minutes while I loaded the violin damping guardian. Also LLO was out of Observe at this time so this was a good opportunity to make the changes.

rahul.kumar@LIGO.ORG - 21:37, Sunday 01 October 2023 (73207)

We lost lock in between, however after a new lock was acquired the above setting still looks to be working fine (2hrs and damping down nicely). I will leave it like this overnight and hopefully if we remain locked then IY05/06 should have made good progress.

rahul.kumar@LIGO.ORG - 08:49, Monday 02 October 2023 (73211)

IY mode 05 and 06 has dropped down by roughly two orders of magnitude since Sat morning - see screenshot attached.

I might try and increase the gain to speed it up.