anthony.sanchez@LIGO.ORG - posted 18:23, Sunday 01 October 2023 (73206)
Lockloss caused by Earthquake 1380243270

Lockloss tool:
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1380243270

This is an interesting Earthquake Lockloss!
SEI went into Earthquake mode at 00:53:02 UTC
We lost lock a minute after that.
Sensors are picking up Big ground motion but Seismon only shows earthquakes from yesterday. And Still has not updated.
Picket Fence clearly picked up the Earthquake in all the traces.
Even USGS didn't tell me where the Earthquake was for over 10 minutes later.
Turns out It was a 4.7 off the coast of Oregon!!

Tagging SEI.
 