OPS Day Shift Summary

TITLE: 10/03 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Austin
SHIFT SUMMARY:

IFO is LOCKING (as of 22:46 UTC)

Notable Activities and Events Regarding Control Room and Tuesday Maintenance Tasks

LOG:                                                                                                                                  

Start Time System Name Location Lazer_Haz Task Time End
15:09           15:10
15:11 FAC Karen EY N Technical Cleaning 16:06
15:13 FAC Randy + Chris + Bubba LVEA N Septum Plate Forklift + Move 17:17
15:13 FAC Kim EX N Technical Cleaning 16:13
15:15 FAC Ken LVEA N Mechanical Room Heaters Check 19:41
15:16 FAC Cindi FCES N Technical Cleaning 16:16
15:23 PEM Mitchell EX/EY N Dust Pump Famis Task 16:11
15:26 FAC Bubba LVEA N Snorkel Lift Ceiling Noise Check 15:57
15:26 FAC Chris LVEA N Pest Control 15:42
15:27 SUS Fernando + Jason LVEA N IX Oplev Laser Swap 15:39
15:33 VAC Jordan + Gerardo + Travis LVEA N Turbo Pumps 17:22
15:41 FAC Chris EY, MY, EX, MX N Pest Control 16:42
15:46 EE Fil CER N ISI IX Coil Driver 16:21
15:49 FAC Tyler MY N Looking at Fans 19:55
16:22 EE Fil CER N Grounding of PSL + Beckhoff Chassis 17:00
16:43 FAC Chris LVEA N First Aid + Eyewash Stations + First Aid (FAMIS) 17:43
16:44 FAC Karen + Kim LVEA N Technical Cleaning 17:17
16:48 VAC Gerardo + Travis FCES N Moving Cleanroom 17:22
17:10 SQZ Sheila + Camilla + Naoki LVEA Local Swapping homodyne at SQZ Table 18:43
17:16 EE Fernando + Marc LVEA, CER, Mezannine N Electrical System Testing 18:46
17:19 FAC Karen + Kim Filter Cavity Tube N Technical Cleaning 19:34
17:22 TCS Ryan C Mechanical Room N Mechanical Room Chiller Check 17:32
17:29 FAC Cindi LVEA Recieving N Cardboard extraction 17:46
17:40 ISC Keita LVEA N Ham 6 Noise Reduction Inspection on OM2 19:45
17:47           17:47
17:48 FAC Cindi High-Bay N Technical Cleaning 18:19
18:13 FAC Chris EX, EY N Eyewash Stations + First Aid (FAMIS) 19:24
18:25 SUS Jason LVEA N IX Oplev Check 18:32
18:32 VAC Gerardo LVEA N More Turbo Pump Work 19:03
18:40 EE Fil LVEA N ISI IX Coil Driver Turn On 18:41
19:02 SUS Jason + Ryan S LVEA, CER N Swapping DC converter power regulator 20:07
19:51 SAF Ryan S + Oli LVEA N Sweep 20:15
20:08 SUS Jason Optics Lab N Dropping off parts (Quick) 20:09
21:33 TCS Camilla LVEA N TCSY Laser Switch-On 21:44
Comments related to this report
camilla.compton@LIGO.ORG - 16:51, Tuesday 03 October 2023 (73256)TCS

At 21:29UTC the CO2Y laser tripped off with RTD/IR alarm. I went into the LVEA and had to power cycle the CO2Y chassis and wobble the IR cable connector box before the laser would turn on again. The VAC team bumped the table earlier today but I doubt this has anything to do with the trip off. I checked the annular pattern on ITMY via the HWS looked as normal.