Reports until 09:34, Tuesday 10 October 2023
H1 TCS
camilla.compton@LIGO.ORG - posted 09:34, Tuesday 10 October 2023 - last comment - 08:55, Tuesday 24 October 2023(73357)
CO2X turned up before IFO Unlocked this morning.

I turned up CO2X 15:05 to 15:12 UTC to see if we could put noise into DARM, plot attached.

We got DARM glitches when raised and lowered the annular mask, see t-cursors attached. This is surprising. We should check that this is from the CO2 laser being blocked while the mask  (on a flipper mount) passes through the beam, rather than any electronics issue. Can do this by turning off CO2 laser and then raising and lowering the mask. 

Still want to redo 72981 line driving once we understand which PD to use for readback.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 08:55, Tuesday 24 October 2023 (73686)

In 73682 showed the glitches were caused by the CO2 beam being quickly blocked rather than any electronics issue.