Reports until 13:59, Wednesday 11 October 2023
H1 ISC
camilla.compton@LIGO.ORG - posted 13:59, Wednesday 11 October 2023 (73384)
PRCL OLG Measurement Taken

As suggested by Elenna/Jenne, ran the /lsc/h1/templates/PRCL/PRCL/PRCL_OLG_NOISE_FULL_LOCK_NLN.xml PRCL open loop gain measurement.

This was with H1:LSC-PRCL1_GAIN at 10 and H1:LSC-PRCL2_GAIN at 1, after 4h35 at NLN. Cursor is on 22.5Hz, gain 1, phase 22.7 deg. Plot attached. This is fine and similar to last measurements (70692, 70664).

Images attached to this report