Reports until 10:50, Thursday 12 October 2023
H1 General (DetChar)
max.trevor@LIGO.ORG - posted 10:50, Thursday 12 October 2023 (73418)
DetChar DQ Shift Report: Oct 2 to Oct 8
Full DQ shift report is at: https://wiki.ligo.org/DetChar/DataQuality/DQShiftLHO20231002
Overall a relatively uneventful week.
Range frequently stable around 150 Mpc with some drops down to 140
Found that hveto was looking at unsafe channels to generate vetos, should be fixed now
Some safe channels also found by hveto as good witnesses:
    H1:PEM-EX_EFM_BSC9_ETMX_Y_OUT_DQ
    H1:SUS-ETMX_L3_OPLEV_PIT_OUT_DQ
    H1:SUS-ETMX_L3_OPLEV_YAW_OUT_DQ

Glitches continue to be problematic, much higher glitch rate than L1.
Some of the glitches most affecting the PyCBC search have werd morphologies
Images attached to this report