Displaying report 1-1 of 1.
Reports until 15:48, Friday 13 October 2023
H1 SUS (OpsInfo)
thomas.shaffer@LIGO.ORG - posted 15:48, Friday 13 October 2023 - last comment - 11:06, Thursday 19 October 2023(73452)
Started making a DARM BLRMS monitor for violin modes

In order to more easily track and notify on rising violin modes, I've started making a DARM BLRMS monitor around 490-520Hz. This is currently in position #8 in place of Camilla 6600-6800Hz that didn't give expected results (alog73272). It looks like its working, but not the best it could be. Jenne gave me some pointers that I'll try at another time to get this to better show us the violin mode total magnitude. Once it's looking acceptable I'll make others for the harmonics as well.

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 11:06, Thursday 19 October 2023 (73591)

Added some more notches for the other harmonics and upped the attenuation on the bandpass. I also took over slot #9 for the 1k violin modes. I think they are working somewhat well, but I'd really like to watch this next time we have a violin mode ring up to see if it's accurate.

Images attached to this comment
Displaying report 1-1 of 1.