Displaying report 1-1 of 1.
Reports until 13:30, Tuesday 17 October 2023
H1 CDS
david.barker@LIGO.ORG - posted 13:30, Tuesday 17 October 2023 - last comment - 13:41, Tuesday 17 October 2023(73523)
CDS Maintenance Summary: Tuesday 17th October 2023

WP11462 Run latest Picket Fence code on nuc5

Edgard, Erik, Dave:

Erik upgraded the userapps git checkout of the picket fence code last Friday, I restarted the code on nuc5 this morning. The only change I made was to add the display of the state borders to the map.

WP11469 Testpoint Stress Test h1pemcs

EJ, Joe, Dave:

With the static DAQ DQ list unchanged, I tested how many testpoints could be opened on h1pemcs.

Result: 62 TPs can be opened (get low level DAQ error if 63 are attempted). PEM measurements require 43 accelerometer TPs, which leaves 19 additional TPs which can be used for PEM injection measurements.

Test code is h1pemcs_testpoint_test.py (web_svn) more details of the test can be found in the comment header block.

WP11468, WP11473 Reconfigure h1didivideo[0,1,2] network ports and reboot

Jonathan, Patrick:

The h1digivideo[0-2] machines were made to be dual-homed, giving the camera LAN a separate ethernet connection. As part of this upgrade, the machines were rebooted which cleared the almost full memory.

WP11477 h1susey BIO readback error

Fil, Rahul, Dave:

Fil and Rahul investigated the ETMY reactionary chain BIO readback, showing F1 DAC drive was in test mode. During the investigation the h1susey front end was fenced from Dolphin and power cycled.

The Contec6464 card for the R0 signals was swapped with a spare:

Removed Card GCRBS96004326
Installed Card ADRBS96001388

The problem was found to be in the cable connecting the Contec6464 card to its BIO Chassis. This means that the removed card is most probably a good card.

Comments related to this report
david.barker@LIGO.ORG - 13:38, Tuesday 17 October 2023 (73525)

Tue17Oct2023
LOC TIME HOSTNAME     MODEL/REBOOT
10:46:30 h1susey      ***REBOOT*** <<< power cycle IO Chassis
10:48:35 h1susey      h1iopsusey  
10:48:48 h1susey      h1susetmy   
10:49:01 h1susey      h1sustmsy   
10:49:14 h1susey      h1susetmypi 


11:29:32 h1susey      ***REBOOT*** <<< replace contec6464
11:31:35 h1susey      h1iopsusey  
11:31:48 h1susey      h1susetmy   
11:32:01 h1susey      h1sustmsy   
11:32:14 h1susey      h1susetmypi 
 
 

david.barker@LIGO.ORG - 13:41, Tuesday 17 October 2023 (73526)

No DAQ restart today, but the reboots of h1susey did cause some frame file MD5 checksum mismatches

DAQ.............Full Frames MD5 Mismatch: [FAIL] 2 MD5 Mismatches [1381600128, 1381602688]
DAQ.....Second Trend Frames MD5 Mismatch: [FAIL] 1 MD5 Mismatches [1381602600]
DAQ.....Minute Trend Frames MD5 Mismatch: [FAIL] 1 MD5 Mismatches [1381597200]
 

Displaying report 1-1 of 1.