Naoki, Sheila, Camilla, Vicky
Summary: After yesterday's crystal move LHO:73535, we re-aligned SQZT7, and now see 8 dB SQZ on the homodyne, up to measured NLG=114 without a phase noise turnaround! This fully resolves the homodyne loss budget, there is 0 mystery loss remaining on the homodyne, from which we can infer 0 mystery losses in HAM7. Back to the IFO afterwards, after 1 day at this new crystal spot, squeezing in DARM is about 4.5dB - 4.8dB, reaching almost 5dB at the start of lock.
We first re-aligned the homodyne to the IFO SQZ alignment, which reached 4.8dB SQZ in DARM yesterday, so we are more confident the alignment back through the VOPO is not clipping. In yesterday's measurements, we had a sign error in the FC-ASC offloading script, which brought us to a bad alignment with limited homodyne squeezing, despite high 98% fringe visibilities. Attached is a screenshot of homodyne FC/ZM slider values with FC+SQZ ASC's fully offloaded (correctly), to which the on-table SQZT7 homodyne is now well-aligned. After Sheila re-aligned the homodyne to the screenshotted FC/ZM values, fringe visibilities are PD1 = 98.5% (loss 3.1%), PD2 = 97.8% (loss 4.2%).
We then did an NLG sweep on the homodyne, from NLG=2.4 (opo trans 20uW) to NLG=114 (opo trans 120uW). Measurements below and attached as .txt, DTT is attached, plots to follow.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
unamplified_ir = 0.0014 (H1:SQZ-OPO_IR_PD_LF_OUT_DQ with pump shuttered)
NLG = amplified / unamplified_ir (opo green pump un-shuttered)
@80uW pump trans, amplified = 0.0198 (at start, 0.0196 at end) --> NLG 0.0198/0.0014 ~ 14
@100uW pump trans, amplified = 0.0046 (at start, 0.0458 at end) --> NLG 0.046/0.0014 = 33
@120uW pump trans, amplified = 0.16 --> NLG 0.16/0.0014 = 114
@60uW pump trans, amplified = 0.011 (at start, 0.0107 at end) --> NLG = 7.86
@40uW pump trans, amplified = 0.0059 (at start, 0.0059 at end) --> NLG = 4.2
@20uW pump trans, amplified = 0.0034 (at start, --- at end) --> NLG = 2.4
| trace | reference | opo_green_trans (uW) | NLG | SQZ dB | CLF RF6 demod angles (+) | 
| LO shot noise @ 1.106 mA, -136.3 dB | 10 | 80 | 14 | ||
| Mean SQZ | 11 | +13 | |||
| SQZ | 12 | -8.0 | 162.0 | ||
| ASQZ | 13 | +16 | 245.44 | ||
| NLG=33 | 100 | 33 | |||
| Mean SQZ | 14 | +16.7 | |||
| SQZ | 15 | -8.0 | 170.5 | ||
| ASQZ | 16 | +19.9 | 237.85 | ||
| NLG = 114 | 120 | 114 | |||
| Mean SQZ | 17 | +22.5 | |||
| SQZ | 19 | -8.0 | 177.98 | ||
| ASQZ | 18 | +25.6 | 230.13 | ||
| NLG = 7.9 | 60 | 7.9 | |||
| Mean SQZ | 20 | +9.7 | |||
| SQZ | 21 | -7.7 | 154.28 | ||
| ASQZ | 22 | +12.4 | 253.83 | ||
| NLG = 4.2 | 40 | 4.2 | |||
| LO SN check | 4 | ~0.1dB lower? | |||
| Mean SQZ | 23 | +6.8 | |||
| SQZ | 24 | -6.3 | 140.6 | ||
| ASQZ | 25 | +9.6 | 262.64 | ||
| NLG = 2.4 | 20 | 2.4 | |||
| Mean SQZ | 26 | +3.8 | |||
| SQZ | 27 | -4.8 | 135.45 | ||
| ASQZ | 28 | +6.3 | -100.5 | ||
| LO shot noise @ 1.06 mA, | 29 | 
All measurements had PUMP_ISS engaged throughout; we manually tuned the ISS setpoint for different NLGs. For low NLG (20uW trans) we manually engaged ISS. LO power (shot noise) drifted ~5% over the measurement, see trends.
NLG Sweep Procedure:
DTT saved in $(userapps)/sqz/h1/Templates/dtt/HD_SQZ/HD_SQZ_8dB_101823_NLGsweep.xml
Using Dhruva's nice plotting code for NLG sweeps from LHO:67242, here are some plots of squeezing vs. NLG, and calibrating the OPO lasing threshold and various green powers at this new crystal spot. Data & updated plotting code attached.
NLG sweep data summary here:
| SHG Launched (mW) | OPO Green Refl (mW) | OPO Green Trans (uW) | NLG | Mean SQZ (dB) | SQZ (dB) | Anti-SQZ (dB) | 
| 10.8 | 1 | 80 | 14 | 13 | -8.0 | 16 | 
| 13.3 | 1.3 | 100 | 33 | 16.7 | -8.0 | 19.9 | 
| 16 | 1.5 | 120 | 114 | 22.5 | -8.0 | 25.6 | 
| 8.4 | 0.8 | 60 | 7.9 | 9.7 | -7.7 | 12.4 | 
| 5.9 | 0.6 | 40 | 4.2 | 6.8 | -6.3 | 9.6 | 
| 3.5 | 0.4 | 20 | 2.4 | 3.8 | -4.8 | 6.3 | 
To-do: Look into the fits of loss & technical noise.
Outstanding work, well done!
Attached here is a re-fitting of this homodyne NLG sweep, which fits [loss, phase noise, technical noise] to measured SQZ+ASQZ, given measured NLG. It also shows the calculated loss from measured mean-sqz and NLG (which relies on accurate calibration of NLG --> generated SQZ dB). The same fitting was done for NLG sweeps on DARM the following week LHO:73747.
The previous anlaysis was fitting [phase noise, technical noise] using the loss calcuated from mean-squeezing. Compared to the earlier analysis, I think these fits here are closer.
We budgeted 13% HD loss for this homodyne measurement: 1 - [0.985(opo) * 0.96(ham7) * 0.98(sqzt7 optics) * 0.977(HD PD QE) * 0.96((visibility~98%)**2)] = 13%.
This fit to the NLG HD sweep suggests ~11% homodyne loss, 7 mrad rms phase noise, with technical noise about -10 dB below 1.1 mW LO shot noise. Note HD dark noise is -22 dB below shot noise, suggesting mystery technical noise on the homodyne.