Displaying report 1-1 of 1.
Reports until 16:39, Thursday 19 October 2023
H1 SEI
anthony.sanchez@LIGO.ORG - posted 16:39, Thursday 19 October 2023 (73604)
H1 ISI CPS Sensor Noise Spectra Check - Weekly FAMIS 25961

FAMIS 25961

Generating BSC pngs...

    
BSC high freq noise is elevated for these sensor(s)!!!
    
ITMX_ST2_CPSINF_H3    
ITMX_ST2_CPSINF_V1    
ITMX_ST2_CPSINF_V3    

    
    
Generating HAM pngs...
Merging pngs to final PDF

final PDF is attached

It looks like HAM7_CPSINF_V3 is elevated compared to the rest of the HAM spectras, but looking back to https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=73295 HAM 7 seems to generally have more noise than the rest of the HAMs on that channel.

Non-image files attached to this report
Displaying report 1-1 of 1.