J. Kissel, J. Driggers I was brainstorming why LOWNOISE_LENGTH_CONTROL would be ringing up a Transmon M1 to M2 wire violin mode (modeled to be at 104.2 Hz for a "production" TMTS; see table 3.11 of T1300876) for the first time on Aug 4 2023 (see current investigation recapped in LHO:72214), and I remembered "TMS tracking..." In short: we found that ETMX M0 L OSEM damping error signal has been fed directly to TMSX M1 L path global control path, without filtering, since Sep 28 2021. Yuck! On Aug 30 2021, I resolved the discrepancies between L1 and H1 end-station SUS front-end models -- see LHO:59772. Included in that work, I cleaned up the Tidal path, cleaned up the "R0 tracking" path (where QUAD L2 gets fed to QUAD R0), and installed the "TMS tracking" path as per ECR E2000186 / LLO:53224. In short, "TMS tracking" couples the ETM M0 longitudinal OSEM error signal to the TMS M1 longitudinal "input to the drivealign bank" global control path, with the intent of matching the velocity of the two top masses to reduce scattered light. On Aug 31 2021, the model changes were installed during an upgrade to the RCG -- see LHO:59797, and we've confirmed that I turned both TMSX and TMSY paths OFF, "to be commissioned later, when we have an IFO, if we need it" at Tuesday -- Aug 31 2021 21:22 UTC (14:22 PDT) However, 28 days later, Tuesday -- Sept 28 2021 22:16 UTC (15:16 PDT) the TMSX filter bank got turned back on, and must have been blindly SDF saved as such -- with no filter in place -- after an EX IO chassis upgrade -- see LHO:60058. At the time, that RCG 4.2.0 still had the infamous "turn on a new filter with its input ON, output ON, and a gain of 1.0" feature, that has been since resolved with RCG 5.1.1. So ... maybe, somehow, even though the filter was already installed on Aug 31 2021, the IO chassis upgrade rebuild, reinstall, and restart of the h1sustmsx.mdl front end model re-registered the filter as new? Unclear. Regardless this direct ETMX M0 L to TMSX M1 L path has been on, without filtering, since Sep 28 2021. Yuck! Jenne confirms the early 2021 timeline in the first attachment here. She also confirms via a ~2 year trend of the H1:SUS-TMSY_M1_FF_L filter bank's SWSTAT, that no filter module has *ever* been turned on, confirmed that there's *never* been filtering. Whether this *is* the source of 102.1288 Hz problems and that that frequency is the TMSX transmon violin mode is still unclear. Brief investigations thus far include - Jenne briefly gathered ASDs of ETMX M0 L (H1:SUS-ETMX_M0_DAMP_L_IN_DQ) and TMSX M1 L OSEMs' error signal (H1:SUS-TMSX_M1_DAMP_L_IN1_DQ) around the time of Oli's LOWNOISE_LENGTH_CONTROL time, but found that at 100 Hz, the OSEMs are limited by their own sensor noise and don't see anything. - She also looked through the MASTER_OUT DAC requests (), in hopes that the requested control signal would show something more or different, but found nothing suspicious around 100 Hz there either. - We HAVE NOT, but could look at H1:SUS-TMSX_M1_DRIVEALIGN_L_OUT_DQ since this FF control filter should be the only control signal going through that path. I'll post a comment with this. Regardless, having this path on with no filter is clearly wrong, so we've turned off the input, output, and gain accepted the filter as OFF, OFF, and OFF in the SDF system (for TMSX, the safe.snap is the same as the observe.snap).
No obvious blast in the (errant) path between ETMX M0 L and TMSX M1 L, the control channel H1:SUS-TMSX_M1_DRIVEALIGN_L_OUT_DQ, during the turn on of the LSC FF. Attached is a screenshot highlighting one recent lock acquisition, after the addition / separation / clean up of calibration line turns ons (LHO:72205): - H1:GRD-ISC_LOCK_STATE_N -- the state number of the main lock acquisition guardian, - H1:LSC-SRCLFF1_GAIN, H1:LSC-PRCLFF_GAIN, H1:MICHFF_GAIN -- EPICs records showing the timing of when the LSC feed forward is turned on - The raw ETMX M0 L damping signal, H1:SUS-ETMX_M0_DAMP_L_IN1_DQ -- stored at 256 Hz - The same signal, mapped (errantly) as a control signal to TMSX M1 L -- also stored at 256 Hz - The TMSX M1 L OSEMs H1:SUS-TMSX_M1_DAMP_L_IN1_DQ, which are too limited by their own self noise to see any of this action -- but also only stored at 256 Hz. In the middle of the TRANSITION_FROM_ETMX (state 557), DARM control is switching from ETMX to some other collection of DARM actuators. That's when you see the ETMX M0 L (and equivalent TMSX_M1_DRIVEALIGN) channels go from relatively noisy to quiet. Then, at the very end of the state, or the start of the next state, LOW_NOISE_ETMX_ESD (state 558), DARM control returns to ETMX, and the main chain top mass, ETMX M0 gets noisy again. Then, several seconds later, in LOWNOISE_LENGTH_CONTROL (state 560), the LSC feed forward gets turned on. So, while there is control request changes to the TMS, at least according to channels stored at 256 Hz, we don't see any obvious kicks / impulses to the TMS during this transition. This decreases my confidence that something was kicking up a TMS violin mode, but not substantially.
@DetChar -- This errant TMS tracking has been on throughout O4 until yesterday. The last substantial nominal low noise segment before the this (with errant, bad TMS tracking) was on 2023-08-15 04:41:02 to 15:30:32 UTC 1376109680 - 1376148650 the first substantial nominal low noise segment after this change 2023-08-16 05:26:08 - present 1376198786 - 1376238848 Apologies for the typo in the main aLOG above, but *the* channels to understand the state of the filter bank that's been turned off are H1:SUS-TMSX_M1_FF_L_SWSTAT H1:SUS-TMSX_M1_FF_L_GAIN if you want to use that for an automated way of determining whether the TMS tracking is on vs. off. If the SWSTAT channel has a value of 37888 and the GAIN channel has a gain of 1.0, then the errant connection between ETMX M0 L and TMSX M1 L was ON. That channels has now a value of 32768 and 0.0, respectively, indicating that it's OFF. (Remember, for a standard filter module a SWSTAT value of 37888 is a bitword representation for "Input, Output, and Decimation switches ON." A SWSTAT value of 32768 is the same bitword representation for just "Decimation ON.") Over the next few weeks, can you build up an assessment of how the IFO has performed a few weeks before vs. few weeks after? I'm thinking, in particular, in the corner of scattered light arches and glitch rates (also from scattered light), but I would happily entertain any other metric you think are interesting given the context. The major difference being that TMSX is no longer "following" ETMX, so there's a *change* in the relative velocity between the chains. No claim yet that this is a *better* change or worse, but there's definitely a change. As you know, the creation of this scattered-light-impacting, relative velocity between the ETM and TMS is related to the low frequency seismic input motion to the chamber, specifically between the 0.05 to 5 Hz region. *That* seismic input evolves and is non-stationary over the few weeks time scale (wind, earthquakes, microseism, etc.), so I'm guessing that you'll need that much "after" data to make a fair comparison against the "before" data. Looking at the channels called out in the lower bit of the aLOG I'm sure will be a helpful part of the investigation. I chose "a few weeks" simply because the IFO configuration has otherwise been pretty stable "before" (e.g., we're in the "representative normal for O4" 60 W configuration rather than the early O4 75 W configuration), but I leave it to y'all's expertise and the data to figure out a fair comparison (maybe only one week, a few days, or even just the single "before" vs. "after" is enough to see a difference).
detchar-request git issue for tracking purposes.
Jane, Debasmita We took a look at the Omicron and Gravity triggers before and after this tracking was turned off. The time segments chosen for this analysis were: TMSX tracking on: 2023-07-29 19:00:00 UTC - 2023-08-15 15:30:00 UTC, ~277 hours observing time TMSX tracking off: 2023-08-16 05:30:00 UTC - 2023-08-31 00:00:00 UTC, ~277 hours observing time For the analysis, the Omicron parameters chosen were SNR > 7.5, and a frequency between 10 Hz and 1024 Hz. The Gravity Spy glitches included a confidence of > 90%. The first pdf contains glitch rate plots. In the first plot, we have the Omicron glitch rate comparison before and after the change. The second and third plots shows the comparison of the Omicron glitch rates before and after the change as a function of SNR and frequency. The fourth plot shows the Gravity Spy classifications of the glitches. What we can see from these plots is that when the errant tracking was on, the overall glitch rate was higher (~29 per hour when on, ~15 per hour when off). It was particularly high in the 7.5-50 SNR range and 10Hz - 50Hz range, which is typically where we observe scattering. The Gravity Spy plot shows that scattered light is the most common glitch type when the tracking is both on and off, but reduces after the tracking is off. We also looked into see if these scattering glitches were coincidence in "H1:GDS-CALIB_STRAIN" and "H1:ASC-X_TR_A_NSUM_OUT_DQ", which is shown in the last pdf. From the few examples we looked at, there does seem to be some excess noise in the transmitted monitor channel when the tracking was on. If necessary, we can look into more examples of this.
Debasmita, Jane We have plotted the ground motion trends in the following frequency bands and DOFs 1. Earthquake band (0.03 Hz--0.1 Hz) ground motion at ETMX-X, ETMX-Z and ETMX-X tilt-subtracted 2. Wind speed (0.03 Hz--0.1 Hz) at ETMX 3. Micro-seismic band (0.1 Hz--0.3 Hz) ground motion at ETMX-X We have also calculated the mean and median of the ground motion trends for two weeks before and after the tracking was turned off. It seems that while motion in all the other bands remained almost same, the microseismic band ground motion (0.1-0.3 Hz) has increased significantly (from a mean value of 75.73 nm/s to 115.82 nm/s) when the TMS-X tracking was turned off. Still, it produced less scattering than before when the TMS-X tracking was on. The plots and the table are the attached here.