I turned up CO2X 15:05 to 15:12 UTC to see if we could put noise into DARM, plot attached.
We got DARM glitches when raised and lowered the annular mask, see t-cursors attached. This is surprising. We should check that this is from the CO2 laser being blocked while the mask (on a flipper mount) passes through the beam, rather than any electronics issue. Can do this by turning off CO2 laser and then raising and lowering the mask.
Still want to redo 72981 line driving once we understand which PD to use for readback.
In 73682 showed the glitches were caused by the CO2 beam being quickly blocked rather than any electronics issue.