Displaying report 1-1 of 1.
Reports until 11:39, Tuesday 24 October 2023
H1 ISC
gabriele.vajente@LIGO.ORG - posted 11:39, Tuesday 24 October 2023 - last comment - 12:45, Wednesday 25 October 2023(73698)
Resonant gains in DARM2

I prepared a new filter module with resonant gains at 2.8 Hz and 3.4 Hz. This can be tried tomorrow (on during some commissioning time) to reduce the DARM RMS and see if it helps the non-stationary noise.

The new FM is loaded into DARM2 FM1 "RG2.8-3.4". It is not engaged now.

 

For future reference, here are the FMs that are used during lock acquisition:

DARM1: FM1 FM2 FM3 FM4 FM7 FM9 FM10

DARM2: FM3 FM4 FM5 FM6 FM7 FM8 FM9 FM10

leaving DARM1 FM5,6,8 and DARM2 FM1,2 unused

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 12:45, Wednesday 25 October 2023 (73737)

Camilla and I turned on DAM2 FM1 from 19:43:37 to 20:05:50 UTC October 25

Displaying report 1-1 of 1.