Here's a BruCo repot for GDS-CALIB_STRAIN_NOLINES from last night lock: https://ldas-jobs.ligo-wa.caltech.edu/~gabriele.vajente/bruco_1382152121_STRAIN/
Some highlights:
- CHARD_Y is likely the leading limiting factor between 10 and 20 Hz, while DHARD_Y is the main contributor to residual noise below 8 Hz (to be confirmed with another BruCo scan on LSC-DARM_IN1
- maybe it's time to retune / recheck the A2L gains
- SRCL is also contributing to a good fraction of the noise between 10 and 20 Hz.
- maybe we can try an iterative retuning of the SRCL FF
- MICH is also not too far between 10 and 50 Hz:
- time to do an iterative retuning of MICH FF
- PRCL shows (surprisingly?) some coherence between 24 and 50 Hz: PRCL could explain the peaks and structures between 24 and 40 Hz
- maybe coupling throuhg MICH? Or is it time to put back in operation a PRCL FF?
Large frequency bands are completely devoid of coherence.