CDS Maintenance Summary: Tuesday 24th October 2023

WP11492 SUSPROC PI PLL model changes

Vladimir, Naoki, Erik, Dave

A new h1susprocpi model was installed. A DAQ restart was required

WP11485 h1hwsmsr disk replacement

Jonathan.

The failed 2TB HDD disk which is part of the /data raid was replaced with a 2TB SSD drive. At time of writing it is 70% done with the new disk rebuild.

Jonathan also cloned the boot disk. I verified that /data is being backed up to LDAS on a daily basis at 5am.

WP11478 Add HOFT and NOLINES H1 effective range to EPICS and DAQ.

Jonathan, Dave:

On Keith's suggestion, the HOFT and NOLINES versions of the H1 effective range were added to the dmt2epics IOC on h1fescript0. The MPC and GPS channels were also added to the H1EPICS_DMT.ini for inclusion into the DAQ. A DAQ restart was required.

WP11488 Deactivate opslogin

Jonathan

The old opslogin machine (not to be confused with opslogin0) was powered down.

WP11479 Add zotvac0 epics monitor channels to DAQ

Dave:

H1EPICS_CDSMON was modified to add zotvac0's channels. A DAQ restart was required.

DAQ Restart

Jonathan, Dave:

The DAQ was restarted for the above changes. This was a very messy restart.

0-leg was restarted. h1gds0 needed a second restart to sync its channel list.

EDC on h1susauxb123 was restarted

8 minutes later fw0 spontaneously restarted itself. At this point h1susauxb123 front end locked up, all models and EDC crashed.

Jonathan connected a local console to h1susauxb123, but there was no errors printed, the keyboard was unresponsive. h1susauxb123 was rebooted.

After the EDC came back online, the DAQ 1-leg was restarted.

h1gds1 needed a second restart to sync up its disks.

Comments related to this report
david.barker@LIGO.ORG - 14:30, Tuesday 24 October 2023 (73707)

Tue24Oct2023
LOC TIME HOSTNAME     MODEL/REBOOT
13:01:42 h1oaf0       h1susprocpi <<< model restart


13:02:34 h1daqdc0     [DAQ]  <<< 0-leg restart
13:02:43 h1daqfw0     [DAQ]
13:02:43 h1daqtw0     [DAQ]
13:02:44 h1daqnds0    [DAQ]
13:02:51 h1daqgds0    [DAQ]
13:03:21 h1susauxb123 h1edc[DAQ] <<< EDC restart
13:03:52 h1daqgds0    [DAQ] <<< 2nd gds0 restart


13:09:26 h1daqfw0     [DAQ]  <<< spontaneous FW0 restart (crash of h1susauxb123 at this point)


13:22:34 h1susauxb123 ***REBOOT*** <<< reboot h1susauxb123, start EDC
13:23:20 h1susauxb123 h1edc[DAQ]
13:23:36 h1susauxb123 h1iopsusauxb123
13:23:49 h1susauxb123 h1susauxb123


13:26:01 h1daqdc1     [DAQ] <<< 1-leg restart
13:26:11 h1daqfw1     [DAQ]
13:26:11 h1daqtw1     [DAQ]
13:26:12 h1daqnds1    [DAQ]
13:26:20 h1daqgds1    [DAQ]
13:26:48 h1daqgds1    [DAQ] <<< 2nd GDS1 restart
 

david.barker@LIGO.ORG - 14:44, Tuesday 24 October 2023 (73708)

DMT2EPICS configuration file, HOFT and NOLINES added:

{
    "prefix": "H1:",
    "entries": [
        {
            "engine": "dmt",
            "config": {
                "url": "https://marble.ligo-wa.caltech.edu/dmtview/SenseMonitor_CAL_H1/H1SNSW%20EFFECTIVE%20RANGE%20%28MPC%29/data.txt",
                "pv-name": "CDS-SENSMON_CAL_SNSW_EFFECTIVE_RANGE_MPC",
                "pv-gps": "CDS-SENSMON_CAL_SNSW_EFFECTIVE_RANGE_MPC_GPS",
                "disconnected-value": -1.0,
                "period": 30.0
            }
        },
        {
            "engine": "dmt",
            "config": {
                "url": "https://marble.ligo-wa.caltech.edu/dmtview/SenseMonitor_Clean_H1/H1SNSC%20EFFECTIVE%20RANGE%20%28MPC%29/data.txt",
                "pv-name": "CDS-SENSMON_CLEAN_SNSC_EFFECTIVE_RANGE_MPC",
                "pv-gps": "CDS-SENSMON_CLEAN_SNSC_EFFECTIVE_RANGE_MPC_GPS",
                "disconnected-value": -1.0,
                "period": 30.0
            }
        },
        {
            "engine": "dmt",
            "config": {
                "url": "https://marble.ligo-wa.caltech.edu/dmtview/SenseMonitor_hoft_H1/H1SNSH%20EFFECTIVE%20RANGE%20%28MPC%29/data.txt",
                "pv-name": "CDS-SENSMON_HOFT_SNSH_EFFECTIVE_RANGE_MPC",
                "pv-gps": "CDS-SENSMON_HOFT_SNSH_EFFECTIVE_RANGE_MPC_GPS",
                "disconnected-value": -1.0,
                "period": 30.0
            }
        },
        {
            "engine": "dmt",
            "config": {
                "url": "https://marble.ligo-wa.caltech.edu/dmtview/SenseMonitor_Nolines_H1/H1SNSL%20EFFECTIVE%20RANGE%20%28MPC%29/data.txt",
                "pv-name": "CDS-SENSMON_NOLINES_SNSL_EFFECTIVE_RANGE_MPC",
                "pv-gps": "CDS-SENSMON_NOLINES_SNSL_EFFECTIVE_RANGE_MPC_GPS",
                "disconnected-value": -1.0,
                "period": 30.0
            }
        }
    ]
}
 

Displaying report 1-1 of 1.