Followed the instruction found here:
https://docs.google.com/document/d/1AXIOEC6XkT9Mp47Ny4aEZu0ucMTprHV0lA-Bu1KJnvk/edit
and ran the following command @ 2:42 UTC and got the following output:
anthony.sanchez@cdsws13: hwinj detchar safety --run
ifo: H1
waveform root: /ligo/groups/cal/H1/hwinj
config file: /ligo/groups/cal/H1/hwinj/hwinj.yaml
GraceDB url: https://gracedb-playground.ligo.org/api/
GraceDB group: Test
GraceDB pipeline: HardwareInjection
excitation channel: H1:CAL-INJ_TRANSIENT_EXC
injection group: detchar
injection name: safety
reading waveform file...
injection waveform file: /ligo/groups/cal/H1/hwinj/detchar/detchar-hwinj-schedule_LIGO-T1900555-PROPOSED_H1_INJECTIONS.txt
injection waveform sample rate: 16384
injection waveform length: 390.0 seconds
reading log file...
injection log file: /ligo/groups/cal/H1/hwinj/detchar/detchar-hwinj-schedule_LIGO-T1900555-PROPOSED_H1_INJECTIONS_log.csv
injection log entries: 75
initiating ligo_proxy_init for GraceDB access...
injection start GPS: 1382236977.6
H1:CAL-INJ_TINJ_TYPE => 3
H1:CAL-INJ_TINJ_TYPE => 3
H1:CAL-INJ_TRANSIENT_SW2 => 1024
H1:CAL-INJ_TRANSIENT_SW2 => 1024
H1::CAL-INJ_TRANSIENT => ON: OUTPUT
H1::CAL-INJ_TRANSIENT => ON: OUTPUT
=== EXECUTING AWG INJECTION ===
this will wait until the injection is nearly complete...
ndshosts: h1daqnds1 and h1daqnds0
getting host by name: h1daqnds1
found host
testpoint_client 1.0.0
found version 4 or newer test point interface
H1:CAL-INJ_TRANSIENT_SW2 => 1024
H1:CAL-INJ_TRANSIENT_SW2 => 1024
H1::CAL-INJ_TRANSIENT => OFF: OUTPUT
H1::CAL-INJ_TRANSIENT => OFF: OUTPUT
H1:CAL-INJ_TINJ_TYPE => 0
H1:CAL-INJ_TINJ_TYPE => 0
=== INJECTION COMPLETE ===
creating injection events in GraceDB...
creating event: Detchar_HW_INJ_H1_1382236987.6.json
creating event: Detchar_HW_INJ_H1_1382236992.6.json
creating event: Detchar_HW_INJ_H1_1382236997.6.json
creating event: Detchar_HW_INJ_H1_1382237002.6.json
creating event: Detchar_HW_INJ_H1_1382237007.6.json
creating event: Detchar_HW_INJ_H1_1382237012.6.json
creating event: Detchar_HW_INJ_H1_1382237017.6.json
creating event: Detchar_HW_INJ_H1_1382237022.6.json
creating event: Detchar_HW_INJ_H1_1382237027.6.json
creating event: Detchar_HW_INJ_H1_1382237032.6.json
creating event: Detchar_HW_INJ_H1_1382237037.6.json
creating event: Detchar_HW_INJ_H1_1382237042.6.json
creating event: Detchar_HW_INJ_H1_1382237047.6.json
creating event: Detchar_HW_INJ_H1_1382237052.6.json
creating event: Detchar_HW_INJ_H1_1382237057.6.json
creating event: Detchar_HW_INJ_H1_1382237062.6.json
creating event: Detchar_HW_INJ_H1_1382237067.6.json
creating event: Detchar_HW_INJ_H1_1382237072.6.json
creating event: Detchar_HW_INJ_H1_1382237077.6.json
creating event: Detchar_HW_INJ_H1_1382237082.6.json
creating event: Detchar_HW_INJ_H1_1382237087.6.json
creating event: Detchar_HW_INJ_H1_1382237092.6.json
creating event: Detchar_HW_INJ_H1_1382237097.6.json
creating event: Detchar_HW_INJ_H1_1382237102.6.json
creating event: Detchar_HW_INJ_H1_1382237107.6.json
creating event: Detchar_HW_INJ_H1_1382237112.6.json
creating event: Detchar_HW_INJ_H1_1382237117.6.json
creating event: Detchar_HW_INJ_H1_1382237122.6.json
creating event: Detchar_HW_INJ_H1_1382237127.6.json
creating event: Detchar_HW_INJ_H1_1382237132.6.json
creating event: Detchar_HW_INJ_H1_1382237137.6.json
creating event: Detchar_HW_INJ_H1_1382237142.6.json
creating event: Detchar_HW_INJ_H1_1382237147.6.json
creating event: Detchar_HW_INJ_H1_1382237152.6.json
creating event: Detchar_HW_INJ_H1_1382237157.6.json
creating event: Detchar_HW_INJ_H1_1382237162.6.json
creating event: Detchar_HW_INJ_H1_1382237167.6.json
creating event: Detchar_HW_INJ_H1_1382237172.6.json
creating event: Detchar_HW_INJ_H1_1382237177.6.json
creating event: Detchar_HW_INJ_H1_1382237182.6.json
creating event: Detchar_HW_INJ_H1_1382237187.6.json
creating event: Detchar_HW_INJ_H1_1382237192.6.json
creating event: Detchar_HW_INJ_H1_1382237197.6.json
creating event: Detchar_HW_INJ_H1_1382237202.6.json
creating event: Detchar_HW_INJ_H1_1382237207.6.json
creating event: Detchar_HW_INJ_H1_1382237212.6.json
creating event: Detchar_HW_INJ_H1_1382237217.6.json
creating event: Detchar_HW_INJ_H1_1382237222.6.json
creating event: Detchar_HW_INJ_H1_1382237227.6.json
creating event: Detchar_HW_INJ_H1_1382237232.6.json
creating event: Detchar_HW_INJ_H1_1382237237.6.json
creating event: Detchar_HW_INJ_H1_1382237242.6.json
creating event: Detchar_HW_INJ_H1_1382237247.6.json
creating event: Detchar_HW_INJ_H1_1382237252.6.json
creating event: Detchar_HW_INJ_H1_1382237257.6.json
creating event: Detchar_HW_INJ_H1_1382237262.6.json
creating event: Detchar_HW_INJ_H1_1382237267.6.json
creating event: Detchar_HW_INJ_H1_1382237272.6.json
creating event: Detchar_HW_INJ_H1_1382237277.6.json
creating event: Detchar_HW_INJ_H1_1382237282.6.json
creating event: Detchar_HW_INJ_H1_1382237287.6.json
creating event: Detchar_HW_INJ_H1_1382237292.6.json
creating event: Detchar_HW_INJ_H1_1382237297.6.json
creating event: Detchar_HW_INJ_H1_1382237302.6.json
creating event: Detchar_HW_INJ_H1_1382237307.6.json
creating event: Detchar_HW_INJ_H1_1382237312.6.json
creating event: Detchar_HW_INJ_H1_1382237317.6.json
creating event: Detchar_HW_INJ_H1_1382237322.6.json
creating event: Detchar_HW_INJ_H1_1382237327.6.json
creating event: Detchar_HW_INJ_H1_1382237332.6.json
creating event: Detchar_HW_INJ_H1_1382237337.6.json
creating event: Detchar_HW_INJ_H1_1382237342.6.json
creating event: Detchar_HW_INJ_H1_1382237347.6.json
creating event: Detchar_HW_INJ_H1_1382237352.6.json
creating event: Detchar_HW_INJ_H1_1382237357.6.json
uploads complete.
anthony.sanchez@cdsws13: