Here is a list of the _known_ corrections to the systematic error that need to be accounted for when regenerating the O4a uncertainty budgets.
| Issue | Start | End | Status |
| 3.2 kHz ESD Driver Pole in CAL-CS Model (LHO:72043) | 2023/04/26 (ER15) | 2023/08/08 00:15 UTC | Rough fit exists. LHO:71787 |
| Spoiled TDCFs due to noise in Kappa_UIM (LHO:71790, LHO:71846) | 2023/07/20 | 2023/08/03 | In progress. Pending correction file. |
| Thermalization effects seen in sensing function at 75W | ER15 | 2023/06/21 | In progress by Cal group. |
| Thermalization effects seen in sensing function at 60W | 2023/06/21 | Now | In progress by Cal group. |
There may be other corrections that are needed by additional unmodeled effects including OM2 hot/cold, drifting Kappa_T, and Pcal error that hasn't been accounted for (if any).
Useful reference:
Record of Real-time Calibration Pipeline Parameter Changes: O4 (and ER15) -- H1 (DCC T2300297)