TITLE: 10/25 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Commissioning
INCOMING OPERATOR: Tony
SHIFT SUMMARY: Now Locked for 20.5 hours. Had commissioning today starting at 19:07UTC and is ongoing but wrapping up soon.
LOG:
15:00UTC Detector Locked for 12.5hours
--Commissioning Start--
19:07 Out of Observing for Commissioning
19:09 To NLN_CAL_MEAS for Calibration measurements
- bb measurements: 1382296233 - 1382296559
- simulines measurements: 1382296585 - 1382297917
19:39 Back to NOMINAL_LOW_NOISE
19:44 - 20:05 DARM Boost
20:08 COMM Gain
12: 20:08:17 - 20:10:17
6: 20:10:29 - 20:12:29
12: 20:12:44 - 20:14:44
6: 20:14:58 - 20:16:58
20:20 - PRESENT SQZ ASQZ w/different NLG
| Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
|---|---|---|---|---|---|---|
| 15:04 | FAC | Karen | OpticLab/VacPrep | n | Tech clean | 15:32 |
| 15:09 | FAC | Randy | EY/EX | n | Moving boxes from EY to EX | 17:09 |
| 15:32 | FAC | Karen | MY | n | Tech clean | 16:48 |
| 19:10 | CAL | Louis, Oli | CR | n | Running calibration | 19:38 |
| 19:49 | OPT | Jason | OpticsLab | y(local) | Oplev work | 20:15 |
| 19:44 | ISC | Camilla, Sheila | CR | n | DARM Boost | 20:06 |
| 20:07 | ISC | Oli | CR | n | CARM gain | 20:17 |
| 19:10 | PI | Vlad, Naoki | CR | n | 80k PI work | 21:34 |
| 20:29 | FAC | Eric, Tyler | MX | n | Looking at air handler | 21:59 |
| 20:20 | SQZ | Sheila, Camilla | CR | n | SQZ ASQZ w/different NLG | ongoing |
| 21:23 | OPT | Jason, Austin | Optics Lab | n | Oplevs | 22:37 |