Displaying report 1-1 of 1.
Reports until 19:11, Wednesday 25 October 2023
H1 CDS
david.barker@LIGO.ORG - posted 19:11, Wednesday 25 October 2023 (73749)
h1cam26 (BS) stopped responding at 17:28, recovered by power cycling the camera

Tony, Dave:

The EPICS channels for cam26 froze at their last values from 17:28 PDT onwards this evening. The camera was recovered by:

1. power cycling the camera via its POE port on sw-lvea-aux (port 0/35)

2. attempting to kill the camera server process on h1digivideo2 using monit, and when that did not work I killed the process by hand as root.

3. started the camera server process via monit, which did work.

Unfortunately H1 had lost lock, so I can only confirm the pixel sum channel went from its stuck value to zero. We will verify the camera is working when we get light back on it.