Displaying report 1-1 of 1.
Reports until 08:08, Sunday 29 October 2023
H1 General
camilla.compton@LIGO.ORG - posted 08:08, Sunday 29 October 2023 - last comment - 08:34, Sunday 29 October 2023(73815)
Ops Day Shift Start

TITLE: 10/29 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 155Mpc
OUTGOING OPERATOR: Austin
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 3mph Gusts, 2mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.14 μm/s
QUICK SUMMARY: IFO has been locked for 3 hours. Plan to do calibration measurements at 11amPT.

There was a lockloss at 10:49UTC 1382611811 after 3h45 at NLN. Followed by an automatic relock (3 locklosses around DRMI locking).

Comments related to this report
camilla.compton@LIGO.ORG - 08:34, Sunday 29 October 2023 (73817)Lockloss

The overnight lockloss had DARM / ETMX looking strange in the 0.5s before, see attached.  We've been noticing this sort of lockloss in the past few weeks, e.g. Oli's 73578 analysis, 73539.

Images attached to this comment
Displaying report 1-1 of 1.