Displaying report 1-1 of 1.
Reports until 15:59, Tuesday 31 October 2023
LHO General
austin.jennings@LIGO.ORG - posted 15:59, Tuesday 31 October 2023 (73864)
Tuesday Shift Summary

TITLE: 10/31 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
INCOMING OPERATOR: Oli
SHIFT SUMMARY:

- 15:14 UTC - ISI ETMX ST1/2 trip on T240, most likely due to high motion from EQs - plot attached

- 16:08 UTC - ISI H7 trip on CPS, cause unknown - plot attached

- 16:37 - ISI H6 trip on GS13, cause unknown - plot attached

- Fire alarm test in OSB - 16:37 - 16:42

- Airhandler alert for CS ~16:45 - H0:FMC-CS_LVEA_REHEAT_2A/3A/3B_DEGF - attached scope, looks like there is a swing, informed Tyler

- ~16:46 - DM alerts for PSL 102ptics Lab/VAC prep alert @ 18:14/19:57 DM 1 @ EX

- Sometime this morning, the Kepco power supply, supplying power to the LSC/ASC IO chassis started making a loud noise, and after further investigation it appears one of the actual fans broke off causing the rattling

LOG:                                                                                                                                                                                                                                                                                                                                                                                                                                     

Start Time System Name Location Lazer_Haz Task Time End
14:58 FAC Randy EX N Installing clean room curtains 16:40
14:59 FAC Kim/Karen LVEA N Tech clean 17:30
15:04 PSL Jeff CR N PMC sweep 15:54
15:07 VAC Jordan LVEA N Install ion pump (Gerardo in @ 15:27) 22:09
15:18 FAC Cindi FCES N Tech clean 17:10
15:25 HWS TJ/Camilla EY YES Replace HWS laser 18:55
15:30 PCAL Tony PCAL lab Y (LOCAL) PCAL work 18:44
15:54 PSL Jenne CR N Refcav alignment 16:26
15:59 SEI Jim Remote N HAM transfer functions 18:25
16:04 SQZ Daniel SQZ tables Y (LOCAL) SQZ alignment/photos 18:29
16:23 FAC Mitch LVEA N Looking for parts 16:53
16:29 CDS Jonathan OSB N GC switch work 17:26
17:30 FAC Karen EY YES Tech clean 18:24
17:31 FAC Kim EX N Tech clean ??
17:32 FAC Cindi LVEA N Move boxes 17:42
17:54 ISC Jenne CR N BS coil driver switching 18:52
18:59 EE Marc/Fernando CER N Investigate rubbing powersupply fan 19:22
19:15 PCAL Tony PCAL Lab Y PCAL work 20:00
19:45 EE Fil CER N Swap Kepco power supply 20:11
19:50 FAC Randy EY N Cleanroom vent prep 22:12
20:02 PCAL Tony/Rick EX YES PCAL measurement 22:44
20:08 VAC Janos/Travis LVEA N Install filters for pumps ??
20:41 ISC Keita HAM 6 N Measure coupling from thermistor current to DARM 21:38
21:02 PSL Fernando OSB N Beckhoff ISC work 22:01
21:11 VAC Janos/Travis MY N Swap scoll pump 22:30
21:21 TOUR Louis/Marc + Co LVEA N LVEA tour 22:30
21:52 HWS TJ/Camilla EX Y HWS work 22:58
22:30 VAC Janos/Jordan FCES N Cross beam installation ??
Images attached to this report