MY and EY Turbo functionality test

FAMIS tasks 24916 and 24940

Procedure checklist for both stations completed.  No issues were identified at this time.

MY: Scroll pump hours: 11395.3

       Turbo pump hours: 206

       Crash bearings: 100%

EY: Scroll pump hours: 205.8

       Turbo pump hours: 1274

       Crash bearings: 100%

Comments related to this report
travis.sadecki@LIGO.ORG - 14:45, Tuesday 31 October 2023 (73879)

The MY turbo station scroll pump was swapped with a newer pump with only 73.2 hours.  The pump with 11395.3 hours will be rebuilt for future deployment.