Reports until 00:48, Wednesday 01 November 2023
H1 General
oli.patane@LIGO.ORG - posted 00:48, Wednesday 01 November 2023 (73890)
Ops EVE Shift End

TITLE: 11/01 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Aligning
INCOMING OPERATOR: Tony
SHIFT SUMMARY:

I eventually was able to get the IMC locked (73887) and adjust PR3, but for the past 2.5 hours the detector has been trying to complete an initial alignment.

Trying to lock detector:

- Started initial alignment

    - Got stuck at ACQUIRE_XARM_IR, which I assumed was because it was "Waiting for sus to settle", and it stayed there for almost 30 minutes.

- Took the detector to DOWN and restarted the initial alignment. This time the DCPD values were going down, but very slowly.

- Tony and I left initial alignment and tried to move through normal locking but lost lock at FIND_IR

- Tried going back into initial alignment again, but got stuck at ACQUIRE_XARM_IR again

- Tony and I still troubleshooting - I think it's maybe possible that although I got the IMC locked and aligned within itself, it might not be aligned with respect to the rest of the detector.


LOG:

23:00UTC Maintenance finishing up

23:15 Starting to try to fix the IMC Locking issue

02:11 After messing with pitch and yaw on MC1 and the IMC PZT for a while, I wasn't able to get them back to the values that they were at at 15:11UTC this morning, which is when the IMC was last in the unlocked state. I got them all as close as they could and then I am now trying to get flashes on MC trans by going to the acquire state on IMC_LOCK

03:56 IMC Locked

04:53 Adjusting PR3 pitch and yaw based on 73854
    - Got pitch within range from ~1 week ago and yaw is much closer but not within range. COMM beatnote is ~-17 before initial alignment

05:21 Started Initial Alignment

05:55 After about 10 minutes in initial alignment, ALIGN_IFO had gotten stuck at ACQUIRE_XARM_IR, so I took the detector to DOWN and restarted the initial alignment

06:11 Got stuck again at the same spot

07:13 Took detector out of initial alignment and attempted to lock normally - failed at FIND_IR