oli.patane@LIGO.ORG - posted 00:30, Friday 03 November 2023 (73948)
Ops EVE Shift End

TITLE: 11/03 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: TJ
SHIFT SUMMARY: Lost lock after 29( I think) hours being locked. Lockloss was probably caused by Dolphin issues(73947), although so far it seems like the issues are documented as occurring 8 seconds after we lost lock, so it's all a bit confusing whether the issues actually caused the lockloss. I had trouble relocking and we kept losing lock at FIND_IR and LOCKING_ALS even after an initial alignment - not sure why that was (maybe related to all the FIND_IR issues from the past few days). We eventually made it back up and just got into Observing. The violins are looking pretty good suprisingly so I will leave the gain for ITMY 5/6 off for now.
LOG:

23:00UTC Observing and Locked for 23.5 hours.

23:53 Ryan C turns on air compresser at VPW (presumeably on for no more than a couple mins)

03:00 Dropped out of Observing due to SQZ_SHG reaching PZT limit (73943)
03:08 I put us back into Observing

04:00:06 Lockloss (73945)
    - 04:15 Errors with DC0, GDS0, FW1, FW0
    - Connections reestablished
    
04:00 LOCKLOSS_SHUTTER_CHECK went to SHUTTER_FAIL - I fixed it by doing what I've done before for the CHECK_SHUTTER issue (72784)
04:12:23 ALS_XARM reports "[INCREASE_FLASHES.run] USERMSG 2: Arm in Fault state! Waiting..."
04:35 Lockloss from FIND_IR right after IR was not found
    - Errors with DC0, GDS0, FW1, FW0
    - Connections reestablished
04:37 I put the detector in DOWN while contacting Dave
04:39 BRSX/Y_STAT nodes in Errors - I just reloaded them and the errors went away (Dave said the errors might just be a result of the computer issues)

05:18 Started relocking again
05:20 Lockloss at LOCKING_ALS

05:22 Lockloss at LOCKING_ALS

05:50 Detector couldn't get past MICH_OFFLOADED, so I went to DOWN and started an Initial Alignment
06:15 Initial alignment completed

06:18 Lockloss at FIND_IR

07:03 Reached NOMINAL_LOW_NOISE
07:22 Observing                                                                                                                                                                                                                                                                                                                        

Start Time System Name Location Lazer_Haz Task Time End
00:41 PCAL Tony, Rick PCal Lab y(local) PCAL work 02:11