State of H1: Observing at 151Mpc
Following an emergency swap of the MSR timing master (see alog 73970), H1 has been recovered, relocked, and just started observing as of 03:37 UTC.
There were several SDF diffs when H1 reached NLN likely caused by models being restarted this evening as part of the timing master swap. The models with SDF diffs were h1hpiham2, h1isietmy, h1isiham7, h1oaf, and h1caley. All of these have been REVERTED as the channels with diffs had been at their previous values for some days prior to this evening's model restarts.