Reports until 16:00, Sunday 05 November 2023
LHO General (TCS)
austin.jennings@LIGO.ORG - posted 16:00, Sunday 05 November 2023 - last comment - 16:18, Sunday 05 November 2023(74004)
Sunday Shift Summary

TITLE: 11/05 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Lock Aquisition
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY:

- Started off with running an IA, which ran through with no issue

- Went through the rotating call list: contacted Daniel, left a message, then called Jim who noticed that all 4 quad ISI SC guardians had not been reset since the master timing was swapped

- After the issue was solved, relocking was automated, back to NLN @ 19:47/OBSERVE @ 20:10

- H1 went into COMMISSIONING @ 21:50 to adjust SQZ temperature/check SQZ angle - attached SDF

- Lockloss @ 22:58, cause unknown

- Relocking:

LOG:

No log for this shift.

Images attached to this report
Comments related to this report
ryan.short@LIGO.ORG - 16:18, Sunday 05 November 2023 (74012)TCS

Adding onto Austin's note about the TCS powers: the CO2Y laser power is lower than previous lock stretches (trend attached). Current power is around 1.59W, and the DIAG_MAIN message shows when below 1.6W. This appears to have started with the lock today after being down for most of last night.