WP11510 h1hwsey IOC simulation
Dave:
I am running a simulation HWS-ETMY EPICS IOC on cdsioc0. This is a python pcaspy file, h1hwsetmy_dummy_ioc.py. Its channel list is a combination of those in the EDC and in the slow controls SDF. For those SDF entries with non-zero set points, the IOC sets its epics to those values to zero the difference counter.
I have undone the temporary changes made while HWS-ETMY was unavailable: green EDC with 86 disconnected channels, set tcshwssdf OBSERVE.snap values to zero.
WP11506 SQZ Beckhoff Slow Controls Code Change
Daniel, Dave:
Daniel's Beckhoff changes resulted in changes to H1EPICS_ECATSQZCS.ini and h1syscssqzsdf monitor.req files. I generated the new H1EDC.ini ready for a DAQ restart. I restarted the h1syscssqzsdf node on h1ecatmon0.
Move CDS WIFI WAP control IOC from opslogin0 to cdsioc0
Dave:
I finally got round to moving the h1_unifi_ioc code from its 'temporary' location on opslogin0 to its permanent location on cdsioc0. This was in response to some issues with nomachine which slowed my restarting this service this morning. h1_unifi_ioc runs under systemd control on cdsioc0 as user ioc, its configuration if under puppet control.
WP11514 h1sqz model changes
Daniel, Jonathan, Dave:
We installed Daniel's latest h1sqz model. This added some slow channels, and renamed two fast channels. DAQ restart was required. We discovered the two fast channels were in the GDS configuation.
DAQ Restart
Jonathan, Dave:
The DAQ and EDC were restarted for the model and Beckhoff changes above.
gds0 had an extended downtime when we found that the renamed RF35->RF24 channels were in the GDS channel list. Once we had resolved that on gds0 and gds1 the restart proceeded with no issues.
Tue07Nov2023
LOC TIME HOSTNAME MODEL/REBOOT
11:55:32 h1lsc0 h1sqz <<< model restart, new DAQ INI
11:57:11 h1daqdc0 [DAQ] <<< 0-leg restart
11:57:23 h1daqfw0 [DAQ]
11:57:24 h1daqnds0 [DAQ]
11:57:24 h1daqtw0 [DAQ]
11:57:32 h1daqgds0 [DAQ]
11:58:50 h1susauxb123 h1edc[DAQ] <<< EDC restart, Beckhoff SQZ
12:08:53 h1daqgds0 [DAQ] <<< GDS got going with fixed channel list
12:11:06 h1daqdc1 [DAQ] <<< 1-leg restart
12:11:18 h1daqfw1 [DAQ]
12:11:18 h1daqtw1 [DAQ]
12:11:19 h1daqnds1 [DAQ]
12:11:27 h1daqgds1 [DAQ] <<< note, no 2nd restart needed today.