Displaying report 1-1 of 1.
Reports until 13:50, Tuesday 07 November 2023
H1 SQZ
naoki.aritomi@LIGO.ORG - posted 13:50, Tuesday 07 November 2023 - last comment - 16:01, Friday 17 November 2023(74068)
FC GR SUS/VCO crossover

I checked the FC GR SUS/VCO crossover as shown in the attached figure. The crossover is about 60 Hz which is much larger than the blue reference on December 2022. This higher GR SUS gain could cause the instability during the transition from GR to IR. I reduced the GR SUS gain from 1 to 0.5 and the crossover became similar to the blue reference. I updated the SQZ_FC guardian to change this gain. Let's see if this helps the recent failure of FC GR to IR transition. 

Images attached to this report
Comments related to this report
naoki.aritomi@LIGO.ORG - 14:23, Wednesday 15 November 2023 (74229)

The green sus gain was defined in GR_SUS_LOCKING state of SQZ_FC guardian as follows.

ezca['SQZ-FC_LSC_INMTRX_SETTING_1_6'] = 0.5

In the previous alog, I changed the green sus gain by changing this line, but I think it is more convenient to define it in sqzparams. So I modified this line as follows.

self.GR_GAIN = sqzparams.fc_green_sus_gain
ezca['SQZ-FC_LSC_INMTRX_SETTING_1_6'] = self.GR_GAIN

And I defined fc_green_sus_gain = 0.5 in sqzparams.

naoki.aritomi@LIGO.ORG - 16:01, Friday 17 November 2023 (74248)

I defined self.GR_GAIN = sqzparams.fc_green_sus_gain also in TRANSITION_IR_LOCKING state.

Displaying report 1-1 of 1.