Displaying report 1-1 of 1.
Reports until 10:03, Tuesday 13 August 2013
H1 SEI
hugo.paris@LIGO.ORG - posted 10:03, Tuesday 13 August 2013 (7414)
HAM Status

Here is the current status of the aLIGO SEI work regarding the HAM chambers. Everything in red is a change from last week's status. Everything in green is available.

 

·         HAM 1

o    HEPI unlocked and running
      Low priority testing 
      One L4C needs to be replaced: H2
      One actuator is weak: V4 It is 20% weaker than its counterparts. Likely clogged. May require replacement further down the line.

·         HAM2

o   ISI: previously commissioned with HEPI locked (recent performance spectra - not calibrated in higher frequencies), currently unlocked, in vacuum

o   HEPI:
     Unlocked 07/23
     Offsets added to the actuation path to successfully reestablish alignment
     To be commissioned, Transfer functions available.

·         HAM 3

o   ISI: previously commissioned with HEPI locked (recent performance spectra - Calibrated), currently unlocked, in vacuum
     Sensor correction installaton started.
     New blend filters installed. aLigo Blend filters on all DOF but RX and RY. eLigo high roll off blend filters on RX and RY. Performance Spectra.

o   HEPI:
     Unlocked 07/23
     Offsets added to the actuation path to successfully reestablish alignment.
     To be commissioned

·         HAM 4 

o   ISI: In chamber, Previously tested during assembly validation, currently locked, no suspension installed, in-vac cables not connected.
     Electronics ready, in field cables ready, in-rack cables ready. Temporary STS cables
     Simulink Model was fixed (GS13 channels mismatch)
     Model is running, and MEDM screens are available in the Sitemap.

o   HEPI: Currently locked, to be commissioned
     Electronics ready, in field cables ready, in-rack cables ready. Temporary STS cables
     Simulink Model was created.
     Model is running, and MEDM screens are available in the Sitemap.

·         HAM 5

o   ISI: In Chamber, Previously tested during assembly validation, currently locked, no suspension installed, in-vac cables not connected,
     Chamber temporarily closed.         
     Electronics ready, in field cables ready, in-rack cables ready. Temporary STS cables
     Simulink Model was fixed (GS13 channels mismatch)
     Model is running, and MEDM screens are available in the Sitemap.

o   HEPI: Currently locked, to be commissioned     
     Electronics ready, in field cables ready, in-rack cables ready. Temporary STS cables
     Simulink Model was created.
     Model is running, and MEDM screens are available in the Sitemap.

 

·         HAM 6

o   ISI: 
     in chamber.
     Unlocked, no SUS
     Simulink Model was fixed (GS13 channels mismatch)
     Mechanical adjustments complete
     Initial in-chamber testing complete, but not validated yet

o   HEPI: Unlocked
     Electronics ready, in field cables ready, in-rack cables ready. Temporary STS cables
     Simulink Model was created.
     Model is running, and MEDM screens are available in the Sitemap.

 

 

·         Guardian:
                            Transition scripts ready
                            Transition scripts
work under guardian interpreter
                            alarm.txt files ready
                            snap files ready

 

 

Displaying report 1-1 of 1.