IMC autolocker is up running

In response to Jeff.K's request I set up the IMC autolocker so that it can automatically lock itself. So far it seems locking without difficulties. The IMC autolocker had been intentionally disabled until this evening for allowing people to run some measurements on the SUS/HEPI/ISIs. Jeff.K is volunteering to remotely run some cross-over measurements which I haven't finished (alog 7369) as a part of the IMC characterization. So Jeff, it is all yours until everybody wakes up !

The autolocker script, which I copied from Chris's original one and temporarily named as rudimentary_autolocker.2013.Aug.12.edition, is running on h1guarian0. It resides in userapps/ioo/h1/scripts/imc which is the usual IMC scripts place.

Comments related to this report
kiwamu.izumi@LIGO.ORG - 20:40, Monday 12 August 2013 (7420)

I forgot to mention one thing: the MC2 suspension was found to be misaligned a lot, resulting in no interferometric signals. It seemed that it had been misaligned since the last Tueday night probably due to some suspension related measurements/activities. Arnaud burt-restored the MC2 to 19:00 of the Tuesday and this brought the MC2 back to a good alignment where we could lock the IMC.