Reports until 15:30, Tuesday 14 November 2023
H1 ISC
thomas.shaffer@LIGO.ORG - posted 15:30, Tuesday 14 November 2023 (74199)
Checked ALSX PLL and PDH UGFs

Sheila, Ryan S, TJ

Today we went down to EX and looked at the UGFs for the PLL and the PDH, and then the I/Q ratio. To do this we connected the SR785 to the correct common mode chassis (Sheila knew which was which as labels were lacking), and then turned on the test output on the medm screen. We then looked at the I/Q ratio and adjusted the demod phase (H1:ALS-X_REFL_A_PHASE_PHASEDEG) to increase this ratio. Started at around 12.5dB @120deg and ended up at 115deg as the ratio become nonsensical with Q approaching 0 (picture). This value is now saved in SDF.

 

  PLL Before PDH Before   PLL After PDH After
UGF 30.7 kHz 16.8 kHz   17.6 kHz 15.0 kHz
Phase margin 45 deg 42 deg   43 deg 45 deg
Gain margin ~5dB ~4dB   ~4dB

~6dB

This isn't a large change, so we don't expect to see much of a difference but it will be good to compare this to EY when we get a chance to get down there.

Images attached to this report