Displaying report 1-1 of 1.
Reports until 19:33, Tuesday 14 November 2023
H1 CAL
ryan.crouch@LIGO.ORG - posted 19:33, Tuesday 14 November 2023 (74212)
Calibration measurement, BB and Simulines

Following the wiki I ran a calibration measurement while LLO was still relocking.

Starting with the BB

NLN calibration screenshot

03:02 NLN to NLN_CAL_MEAS

03:04 Broadband measurement started:

03:09 Simulines:

PST start: 2023-11-14 19:09:20.280160 PST
UTC start: 2023-11-15 03:09:20.280160 UTC
GPS start: 1384052978.280160

2023-11-15 03:31:25,595 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20231115T030922Z.hdf5
2023-11-15 03:31:25,644 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20231115T030922Z.hdf5
2023-11-15 03:31:25,657 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20231115T030922Z.hdf5
2023-11-15 03:31:25,671 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20231115T030922Z.hdf5
2023-11-15 03:31:25,683 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20231115T030922Z.hdf5

PST end: 2023-11-14 19:31:25.778909 PST
UTC end: 2023-11-15 03:31:25.778909 UTC
GPS end: 1384054303.778909

 

Images attached to this report
Displaying report 1-1 of 1.