Reports until 14:18, Wednesday 15 November 2023
H1 SQZ
naoki.aritomi@LIGO.ORG - posted 14:18, Wednesday 15 November 2023 (74228)
FC IR OLG

I measured FC IR OLG as shown in the attached figure. The FC IR OLG is higher than the purple reference on March 2023. So I decreased the IR gain from -5 to -3.5 and the OLG became similar to the purple reference. I updated the fc_wfs_a_ir_gain in sqzparams and loaded SQZ_FC guardian.

Images attached to this report