Reports until 14:52, Tuesday 21 November 2023
H1 CDS (SEI, SUS)
filiberto.clara@LIGO.ORG - posted 14:52, Tuesday 21 November 2023 (74344)
EX SUS Hardware Watch Dog

WP 11532

Functionality of the ETMX SUS Hardware Watchdog was tested this morning. System had reported no triggers over the past few months. One of the DB37 field cables was disconnected. Both the software and front panel LEDs went into alarm. Field cable was reconnected and system returned to nominal state.