TITLE: 11/27 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 144Mpc
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 3mph Gusts, 2mph 5min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.24 μm/s
QUICK SUMMARY:
- IFO locked for just under 21 hours
- Microseism looks to finally be calm
- CDS ok
- DM PSL 102 needs to be restarted
ETMY mode1, and ITMX mode 12 are slowly ringing up under its current settings, turning off the gain for a bit then I'll try a sign change.
I've had success with the following settings, the spreadsheet has been updated with these as well.
ETMY1: FM1+FM10 G=-0.2
ITMX12: FM1+FM6+FM10 G=+1