Displaying report 1-1 of 1.
Reports until 07:58, Monday 27 November 2023
LHO General
austin.jennings@LIGO.ORG - posted 07:58, Monday 27 November 2023 - last comment - 12:59, Monday 27 November 2023(74422)
Ops Day Shift Start

TITLE: 11/27 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 144Mpc
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 3mph Gusts, 2mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.24 μm/s 
QUICK SUMMARY:

- IFO locked for just under 21 hours

- Microseism looks to finally be calm

- CDS ok

- DM PSL 102 needs to be restarted

Comments related to this report
ryan.crouch@LIGO.ORG - 09:32, Monday 27 November 2023 (74425)SUS

ETMY mode1, and ITMX mode 12 are slowly ringing up under its current settings, turning off the gain for a bit then I'll try a sign change.

Images attached to this comment
ryan.crouch@LIGO.ORG - 12:59, Monday 27 November 2023 (74430)SUS

I've had success with the following settings, the spreadsheet has been updated with these as well.

ETMY1: FM1+FM10 G=-0.2

ITMX12: FM1+FM6+FM10 G=+1

Displaying report 1-1 of 1.