Displaying report 1-1 of 1.
Reports until 10:25, Monday 27 November 2023
LHO VE
david.barker@LIGO.ORG - posted 10:25, Monday 27 November 2023 (74429)
Mon CP1 Fill, trip temp change is required

Mon Nov 27 10:04:41 2023 INFO: Fill completed in 4min 38secs

Jordan confirmed a good fill curbside.

The fill only barely completed, TC-A flat lined at -90.0C and for just one sample went to -90.1C which triggered the end-of-fill. I've increased the trip temp to -80C. The site is experiencing freezing fog, temp=-3C. I suspect TC icing may be an issue.

Images attached to this report
Displaying report 1-1 of 1.